Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristicC
Voltage typeAC
Rated voltage400V
Frequency50 - 60Hz
Over voltage category3
Current limiting class3
Rated insulation voltage Ui500V
Rated current16A
Built-in depth72mm
Width in number of modular spacings2
Degree of protection (IP)IP20
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Power loss4.98W
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Pollution degree3
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Flush-mounted installationNo
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92047

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

C

Voltage type

AC

Rated voltage

400V

Frequency

50 .. 60Hz

Over voltage category

3

Current limiting class

3

Rated insulation voltage Ui

500V

Rated current

16A

Built-in depth

72mm

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Power loss

4.98W

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Pollution degree

3

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Flush-mounted installation

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.