Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Release characteristicC
Number of poles (total)3
Rated current10A
Rated insulation voltage Ui500V
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Frequency50 - 60Hz
Power loss5.94W
Current limiting class3
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Over voltage category3
Pollution degree3
Flush-mounted installationNo
Width in number of modular spacings3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92066 | MCB 3P C10 6KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

C

Number of poles (total)

3

Rated current

10A

Rated insulation voltage Ui

500V

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Frequency

50 .. 60Hz

Power loss

5.94W

Current limiting class

3

Concurrently switching neutral conductor

Additional equipment possible

Over voltage category

3

Pollution degree

3

Flush-mounted installation

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.