  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Power loss7.41W
Explosion-proofNo
Release characteristicC
Connectable conductor cross section solid-core35 - 35mm²
Pollution degree3
Current limiting class3
Built-in depth72mm
Number of protected poles3
Concurrently switching neutral conductorNo
Rated insulation voltage Ui500V
Degree of protection (IP)IP20
Voltage typeAC
Over voltage category3
Rated current20A
Width in number of modular spacings3
Connectable conductor cross section multi-wired35 - 35mm²
Rated voltage400V
Frequency50 - 60Hz
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92068

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Power loss

7.41W

Explosion-proof

Release characteristic

C

Connectable conductor cross section solid-core

35 .. 35mm²

Pollution degree

3

Current limiting class

3

Built-in depth

72mm

Number of protected poles

3

Concurrently switching neutral conductor

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP20

Voltage type

AC

Over voltage category

3

Rated current

20A

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated voltage

400V

Frequency

50 .. 60Hz

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.