Technical specifications

Voltage typeAC
Current limiting class3
Release characteristicC
Built-in depth72mm
Rated insulation voltage Ui500V
Rated current13A
Frequency50 - 60Hz
Over voltage category3
Rated voltage400V
Pollution degree3
Explosion-proofNo
Degree of protection (IP)IP20
Number of protected poles3
Width in number of modular spacings3
Concurrently switching neutral conductorNo
Power loss5.91W
Additional equipment possibleYes
Number of poles (total)3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Connectable conductor cross section multi-wired35 - 35mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92074

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Current limiting class

3

Release characteristic

C

Built-in depth

72mm

Rated insulation voltage Ui

500V

Rated current

13A

Frequency

50 .. 60Hz

Over voltage category

3

Rated voltage

400V

Pollution degree

3

Explosion-proof

Degree of protection (IP)

IP20

Number of protected poles

3

Width in number of modular spacings

3

Concurrently switching neutral conductor

Power loss

5.91W

Additional equipment possible

Number of poles (total)

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA