Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated current4A
Built-in depth72mm
Voltage typeAC
Rated insulation voltage Ui500V
Release characteristicC
Frequency50 - 60Hz
Current limiting class3
Rated voltage400V
Number of protected poles4
Degree of protection (IP)IP20
Flush-mounted installationNo
Pollution degree3
Explosion-proofNo
Over voltage category3
Power loss8.8W
Width in number of modular spacings4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Number of poles (total)4
Additional equipment possibleYes
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92084

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

4A

Built-in depth

72mm

Voltage type

AC

Rated insulation voltage Ui

500V

Release characteristic

C

Frequency

50 .. 60Hz

Current limiting class

3

Rated voltage

400V

Number of protected poles

4

Degree of protection (IP)

IP20

Flush-mounted installation

Pollution degree

3

Explosion-proof

Over voltage category

3

Power loss

8.8W

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Number of poles (total)

4

Additional equipment possible

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor