Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui500V
Over voltage category3
Frequency50 - 60Hz
Rated voltage400V
Release characteristicC
Current limiting class3
Rated current10A
Pollution degree3
Voltage typeAC
Built-in depth72mm
Degree of protection (IP)IP20
Width in number of modular spacings4
Power loss7.92W
Explosion-proofNo
Number of protected poles4
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Ambient temperature during operating-25 - 60°C
Number of poles (total)4
Flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92086

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Over voltage category

3

Frequency

50 .. 60Hz

Rated voltage

400V

Release characteristic

C

Current limiting class

3

Rated current

10A

Pollution degree

3

Voltage type

AC

Built-in depth

72mm

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Power loss

7.92W

Explosion-proof

Number of protected poles

4

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

4

Flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.