Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Current limiting class3
Built-in depth72mm
Rated insulation voltage Ui500V
Over voltage category3
Rated voltage400V
Release characteristicC
Rated current25A
Pollution degree3
Degree of protection (IP)IP20
Power loss8.96W
Width in number of modular spacings4
Number of protected poles4
Explosion-proofNo
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Flush-mounted installationNo
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92089

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Current limiting class

3

Built-in depth

72mm

Rated insulation voltage Ui

500V

Over voltage category

3

Rated voltage

400V

Release characteristic

C

Rated current

25A

Pollution degree

3

Degree of protection (IP)

IP20

Power loss

8.96W

Width in number of modular spacings

4

Number of protected poles

4

Explosion-proof

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Flush-mounted installation

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.