Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated voltage400V
Number of protected poles4
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core35 - 35mm²
Width in number of modular spacings4
Voltage typeAC
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Current limiting class3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Power loss19.68W
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Explosion-proofNo
Additional equipment possibleYes
Over voltage category3
Pollution degree3
Rated current63A
Release characteristicC
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92093 | MCB 4P C63 6KA 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated voltage

400V

Number of protected poles

4

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

35 .. 35mm²

Width in number of modular spacings

4

Voltage type

AC

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Power loss

19.68W

Concurrently switching neutral conductor

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Explosion-proof

Additional equipment possible

Over voltage category

3

Pollution degree

3

Rated current

63A

Release characteristic

C

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.