Technical specifications

Built-in depth72mm
Number of protected poles2
Rated voltage400V
Rated insulation voltage Ui500V
Pollution degree3
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Additional equipment possibleYes
Over voltage category3
Power loss9.56W
Explosion-proofNo
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Width in number of modular spacings2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Rated current50A
Release characteristicB
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92252 | MCB 2P B50 6KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Number of protected poles

2

Rated voltage

400V

Rated insulation voltage Ui

500V

Pollution degree

3

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Additional equipment possible

Over voltage category

3

Power loss

9.56W

Explosion-proof

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Rated current

50A

Release characteristic

B

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA