Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Number of protected poles3
Pollution degree3
Over voltage category3
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
Frequency50 - 60Hz
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Connectable conductor cross section multi-wired35 - 35mm²
Flush-mounted installationNo
Current limiting class3
Connectable conductor cross section solid-core35 - 35mm²
Width in number of modular spacings3
Explosion-proofNo
Power loss7.41W
Rated current20A
Release characteristicB
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92268 | MCB 3P B20 6KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Number of protected poles

3

Pollution degree

3

Over voltage category

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Frequency

50 .. 60Hz

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Flush-mounted installation

Current limiting class

3

Connectable conductor cross section solid-core

35 .. 35mm²

Width in number of modular spacings

3

Explosion-proof

Power loss

7.41W

Rated current

20A

Release characteristic

B

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.