Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Number of protected poles4
Rated insulation voltage Ui500V
Rated voltage400V
Pollution degree3
Width in number of modular spacings4
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Connectable conductor cross section solid-core35 - 35mm²
Power loss7.92W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Explosion-proofNo
Over voltage category3
Additional equipment possibleYes
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Current limiting class3
Frequency50 - 60Hz
Connectable conductor cross section multi-wired35 - 35mm²
Rated current10A
Release characteristicB
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92286 | MCB 4P B10 6KA 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Number of protected poles

4

Rated insulation voltage Ui

500V

Rated voltage

400V

Pollution degree

3

Width in number of modular spacings

4

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Connectable conductor cross section solid-core

35 .. 35mm²

Power loss

7.92W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Explosion-proof

Over voltage category

3

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Current limiting class

3

Frequency

50 .. 60Hz

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated current

10A

Release characteristic

B

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA