Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Rated current20A
Rated voltage400V
Built-in depth72mm
Frequency50 - 60Hz
Current limiting class3
Width in number of modular spacings4
Over voltage category3
Rated insulation voltage Ui500V
Release characteristicB
Concurrently switching neutral conductorNo
Pollution degree3
Power loss9.88W
Degree of protection (IP)IP20
Number of protected poles4
Explosion-proofNo
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Number of poles (total)4
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92288

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Rated current

20A

Rated voltage

400V

Built-in depth

72mm

Frequency

50 .. 60Hz

Current limiting class

3

Width in number of modular spacings

4

Over voltage category

3

Rated insulation voltage Ui

500V

Release characteristic

B

Concurrently switching neutral conductor

Pollution degree

3

Power loss

9.88W

Degree of protection (IP)

IP20

Number of protected poles

4

Explosion-proof

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Number of poles (total)

4

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.