Technical specifications

Power loss14.92W
Explosion-proofNo
Rated voltage400V
Over voltage category3
Current limiting class3
Voltage typeAC
Rated insulation voltage Ui500V
Concurrently switching neutral conductorNo
Rated current40A
Number of protected poles4
Connectable conductor cross section multi-wired35 - 35mm²
Frequency50 - 60Hz
Pollution degree3
Degree of protection (IP)IP20
Width in number of modular spacings4
Connectable conductor cross section solid-core35 - 35mm²
Built-in depth72mm
Release characteristicB
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Number of poles (total)4
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92291

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Power loss

14.92W

Explosion-proof

Rated voltage

400V

Over voltage category

3

Current limiting class

3

Voltage type

AC

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Rated current

40A

Number of protected poles

4

Connectable conductor cross section multi-wired

35 .. 35mm²

Frequency

50 .. 60Hz

Pollution degree

3

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Connectable conductor cross section solid-core

35 .. 35mm²

Built-in depth

72mm

Release characteristic

B

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Number of poles (total)

4

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV