Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Voltage typeAC
Release characteristicB
Rated voltage400V
Rated current50A
Current limiting class3
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Over voltage category3
Pollution degree3
Width in number of modular spacings4
Explosion-proofNo
Number of protected poles4
Concurrently switching neutral conductorNo
Power loss19.12W
Additional equipment possibleYes
Degree of protection (IP)IP20
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 60°C
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92292

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Voltage type

AC

Release characteristic

B

Rated voltage

400V

Rated current

50A

Current limiting class

3

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

4

Explosion-proof

Number of protected poles

4

Concurrently switching neutral conductor

Power loss

19.12W

Additional equipment possible

Degree of protection (IP)

IP20

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.