Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Over voltage category3
Voltage typeAC
Built-in depth72mm
Current limiting class3
Rated current40A
Frequency50 - 60Hz
Release characteristicD
Rated insulation voltage Ui500V
Rated voltage400V
Pollution degree3
Number of poles (total)2
Degree of protection (IP)IP20
Flush-mounted installationNo
Connectable conductor cross section solid-core35 - 35mm²
Width in number of modular spacings2
Number of protected poles2
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Additional equipment possibleYes
Power loss6.24W
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92451

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Over voltage category

3

Voltage type

AC

Built-in depth

72mm

Current limiting class

3

Rated current

40A

Frequency

50 .. 60Hz

Release characteristic

D

Rated insulation voltage Ui

500V

Rated voltage

400V

Pollution degree

3

Number of poles (total)

2

Degree of protection (IP)

IP20

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²

Width in number of modular spacings

2

Number of protected poles

2

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Additional equipment possible

Power loss

6.24W

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.