Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 M
  • GEWISS

Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Rated current20A
Rated insulation voltage Ui500V
Rated voltage400V
Current limiting class3
Over voltage category3
Width in number of modular spacings4
Power loss6.56W
Pollution degree3
Built-in depth72mm
Release characteristicD
Degree of protection (IP)IP20
Explosion-proofNo
Number of protected poles4
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Additional equipment possibleYes
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92488

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 M
  • GEWISS

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Rated current

20A

Rated insulation voltage Ui

500V

Rated voltage

400V

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

4

Power loss

6.56W

Pollution degree

3

Built-in depth

72mm

Release characteristic

D

Degree of protection (IP)

IP20

Explosion-proof

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Additional equipment possible

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.