Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Flush-mounted installationNo
Frequency50 - 60Hz
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Power loss9.36W
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of poles (total)4
Number of protected poles4
Release characteristicD
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current32A
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Width in number of modular spacings4
Over voltage category3
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core35 - 35mm²
Pollution degree3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92490 | MCB 4P D32 6KA 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Flush-mounted installation

Frequency

50 .. 60Hz

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Power loss

9.36W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of poles (total)

4

Number of protected poles

4

Release characteristic

D

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

32A

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Width in number of modular spacings

4

Over voltage category

3

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

35 .. 35mm²

Pollution degree

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.