Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Release characteristicC
Rated current25A
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Rated voltage400V
Number of protected poles2
Rated insulation voltage Ui500V
Voltage typeAC
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Pollution degree3
Current limiting class3
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Over voltage category3
Power loss4.48W
Flush-mounted installationNo
Width in number of modular spacings2
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92649 | MCB 2P C25 10KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

C

Rated current

25A

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Concurrently switching neutral conductor

Additional equipment possible

Rated voltage

400V

Number of protected poles

2

Rated insulation voltage Ui

500V

Voltage type

AC

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

3

Current limiting class

3

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Over voltage category

3

Power loss

4.48W

Flush-mounted installation

Width in number of modular spacings

2

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²