  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristicC
Rated voltage400V
Voltage typeAC
Rated current20A
Frequency50 - 60Hz
Built-in depth72mm
Rated insulation voltage Ui500V
Over voltage category3
Current limiting class3
Explosion-proofNo
Power loss9.88W
Pollution degree3
Width in number of modular spacings4
Degree of protection (IP)IP20
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Additional equipment possibleYes
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92688

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

C

Rated voltage

400V

Voltage type

AC

Rated current

20A

Frequency

50 .. 60Hz

Built-in depth

72mm

Rated insulation voltage Ui

500V

Over voltage category

3

Current limiting class

3

Explosion-proof

Power loss

9.88W

Pollution degree

3

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Additional equipment possible

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.