Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Frequency50 - 60Hz
Explosion-proofNo
Flush-mounted installationNo
Pollution degree3
Power loss6.24W
Width in number of modular spacings2
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Voltage typeAC
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 60°C
Over voltage category3
Rated current40A
Release characteristicD
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92751 | MCB 2P D40 10KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Frequency

50 .. 60Hz

Explosion-proof

Flush-mounted installation

Pollution degree

3

Power loss

6.24W

Width in number of modular spacings

2

Additional equipment possible

Concurrently switching neutral conductor

Voltage type

AC

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Over voltage category

3

Rated current

40A

Release characteristic

D

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA