Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Voltage typeAC
Concurrently switching neutral conductorNo
Rated insulation voltage Ui500V
Explosion-proofNo
Release characteristicD
Over voltage category3
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of protected poles3
Additional equipment possibleYes
Width in number of modular spacings3
Current limiting class3
Power loss9.36W
Pollution degree3
Number of poles (total)3
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated voltage400V
Connectable conductor cross section solid-core35 - 35mm²
Ambient temperature during operating-25 - 60°C
Frequency50 - 60Hz
Rated current1A
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92761

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Voltage type

AC

Concurrently switching neutral conductor

Rated insulation voltage Ui

500V

Explosion-proof

Release characteristic

D

Over voltage category

3

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of protected poles

3

Additional equipment possible

Width in number of modular spacings

3

Current limiting class

3

Power loss

9.36W

Pollution degree

3

Number of poles (total)

3

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated voltage

400V

Connectable conductor cross section solid-core

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Frequency

50 .. 60Hz

Rated current

1A

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.