Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Frequency50 - 60Hz
Current limiting class3
Number of poles (total)3
Rated voltage400V
Rated current1A
Number of protected poles3
Release characteristicD
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Power loss9.36W
Width in number of modular spacings3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Over voltage category3
Additional equipment possibleYes
Pollution degree3
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92761 | MCB 3P D1 10KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Frequency

50 .. 60Hz

Current limiting class

3

Number of poles (total)

3

Rated voltage

400V

Rated current

1A

Number of protected poles

3

Release characteristic

D

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Power loss

9.36W

Width in number of modular spacings

3

Flush-mounted installation

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Over voltage category

3

Additional equipment possible

Pollution degree

3

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.