Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Number of poles (total)3
Release characteristicD
Number of protected poles3
Rated current3A
Rated voltage400V
Rated insulation voltage Ui500V
Voltage typeAC
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Over voltage category3
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Width in number of modular spacings3
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Flush-mounted installationNo
Current limiting class3
Pollution degree3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Explosion-proofNo
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92763 | MCB 3P D3 10KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Number of poles (total)

3

Release characteristic

D

Number of protected poles

3

Rated current

3A

Rated voltage

400V

Rated insulation voltage Ui

500V

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Over voltage category

3

Concurrently switching neutral conductor

Additional equipment possible

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Flush-mounted installation

Current limiting class

3

Pollution degree

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Explosion-proof

Connectable conductor cross section solid-core

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.