Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Voltage typeAC
Rated current6A
Frequency50 - 60Hz
Power loss3.12W
Number of protected poles2
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Width in number of modular spacings2
Release characteristicB
Pollution degree3
Current limiting class3
Concurrently switching neutral conductorNo
Rated insulation voltage Ui500V
Over voltage category3
Rated voltage400V
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Number of poles (total)2
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wired35 - 35mm²
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92545

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Voltage type

AC

Rated current

6A

Frequency

50 .. 60Hz

Power loss

3.12W

Number of protected poles

2

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Width in number of modular spacings

2

Release characteristic

B

Pollution degree

3

Current limiting class

3

Concurrently switching neutral conductor

Rated insulation voltage Ui

500V

Over voltage category

3

Rated voltage

400V

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Number of poles (total)

2

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.