Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Release characteristicB
Rated current6A
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Number of protected poles2
Rated voltage400V
Current limiting class3
Frequency50 - 60Hz
Power loss3.12W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeAC
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Width in number of modular spacings2
Degree of protection (IP)IP20
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Explosion-proofNo
Over voltage category3
Pollution degree3
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92545 | MCB 2P B6 10KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

B

Rated current

6A

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Number of protected poles

2

Rated voltage

400V

Current limiting class

3

Frequency

50 .. 60Hz

Power loss

3.12W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Explosion-proof

Over voltage category

3

Pollution degree

3

Connectable conductor cross section solid-core

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.