Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Number of poles (total)2
Number of protected poles2
Release characteristicB
Rated insulation voltage Ui500V
Rated current16A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Flush-mounted installationNo
Voltage typeAC
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Concurrently switching neutral conductorNo
Pollution degree3
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Power loss4.98W
Frequency50 - 60Hz
Width in number of modular spacings2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired35 - 35mm²
Explosion-proofNo
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92548 | MCB 2P B16 10KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Number of poles (total)

2

Number of protected poles

2

Release characteristic

B

Rated insulation voltage Ui

500V

Rated current

16A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Flush-mounted installation

Voltage type

AC

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Concurrently switching neutral conductor

Pollution degree

3

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Power loss

4.98W

Frequency

50 .. 60Hz

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Explosion-proof

Connectable conductor cross section solid-core

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.