Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Release characteristicB
Rated insulation voltage Ui500V
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated current32A
Number of protected poles2
Number of poles (total)2
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Frequency50 - 60Hz
Power loss6.04W
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Pollution degree3
Flush-mounted installationNo
Additional equipment possibleYes
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Explosion-proofNo
Over voltage category3
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92551 | MCB 2P B32 10KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

B

Rated insulation voltage Ui

500V

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Rated current

32A

Number of protected poles

2

Number of poles (total)

2

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Frequency

50 .. 60Hz

Power loss

6.04W

Concurrently switching neutral conductor

Width in number of modular spacings

2

Pollution degree

3

Flush-mounted installation

Additional equipment possible

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Explosion-proof

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C