Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated current40A
Number of poles (total)2
Rated voltage400V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Voltage typeAC
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Power loss7.46W
Number of protected poles2
Current limiting class3
Frequency50 - 60Hz
Over voltage category3
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92552 | MCB 2P B40 10KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated current

40A

Number of poles (total)

2

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Power loss

7.46W

Number of protected poles

2

Current limiting class

3

Frequency

50 .. 60Hz

Over voltage category

3

Concurrently switching neutral conductor

Flush-mounted installation

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Explosion-proof