Technical specifications

Built-in depth72mm
Number of protected poles3
Release characteristicB
Number of poles (total)3
Rated insulation voltage Ui500V
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V12.5kA
Current limiting class3
Power loss14.34W
Flush-mounted installationNo
Rated voltage400V
Rated current50A
Connectable conductor cross section multi-wired35 - 35mm²
Concurrently switching neutral conductorNo
Pollution degree3
Connectable conductor cross section solid-core35 - 35mm²
Additional equipment possibleYes
Width in number of modular spacings3
Over voltage category3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92573 | MCB 3P B50 10KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Number of protected poles

3

Release characteristic

B

Number of poles (total)

3

Rated insulation voltage Ui

500V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

12.5kA

Current limiting class

3

Power loss

14.34W

Flush-mounted installation

Rated voltage

400V

Rated current

50A

Connectable conductor cross section multi-wired

35 .. 35mm²

Concurrently switching neutral conductor

Pollution degree

3

Connectable conductor cross section solid-core

35 .. 35mm²

Additional equipment possible

Width in number of modular spacings

3

Over voltage category

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Explosion-proof