Technical specifications

Built-in depth72mm
Release characteristicB
Number of poles (total)4
Number of protected poles4
Rated current6A
Rated voltage400V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Power loss6.24W
Current limiting class3
Flush-mounted installationNo
Over voltage category3
Concurrently switching neutral conductorNo
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings4
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92585 | MCB 4P B6 10KA 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

B

Number of poles (total)

4

Number of protected poles

4

Rated current

6A

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Power loss

6.24W

Current limiting class

3

Flush-mounted installation

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Connectable conductor cross section solid-core

35 .. 35mm²