Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Frequency50 - 60Hz
Number of protected poles4
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Release characteristicB
Rated current16A
Over voltage category3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Power loss9.96W
Current limiting class3
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Voltage typeAC
Flush-mounted installationNo
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings4
Additional equipment possibleYes
Pollution degree3
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92588 | MCB 4P B16 10KA 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Frequency

50 .. 60Hz

Number of protected poles

4

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Release characteristic

B

Rated current

16A

Over voltage category

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

9.96W

Current limiting class

3

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Voltage type

AC

Flush-mounted installation

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

4

Additional equipment possible

Pollution degree

3

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.