Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage400V
Rated current20A
Voltage typeAC
Built-in depth72mm
Frequency50 - 60Hz
Release characteristicC
Explosion-proofNo
Over voltage category3
Pollution degree2
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Rated insulation voltage Ui500V
Number of protected poles1
Power loss2.47W
Width in number of modular spacings1
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Number of poles (total)1
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92808

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

400V

Rated current

20A

Voltage type

AC

Built-in depth

72mm

Frequency

50 .. 60Hz

Release characteristic

C

Explosion-proof

Over voltage category

3

Pollution degree

2

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Rated insulation voltage Ui

500V

Number of protected poles

1

Power loss

2.47W

Width in number of modular spacings

1

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Number of poles (total)

1

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.