Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated current6A
Built-in depth72mm
Rated voltage400V
Release characteristicC
Frequency50 - 60Hz
Voltage typeAC
Pollution degree2
Number of protected poles2
Width in number of modular spacings2
Over voltage category3
Explosion-proofNo
Power loss3.12W
Degree of protection (IP)IP20
Rated insulation voltage Ui500V
Number of poles (total)2
Connectable conductor cross section multi-wired35 - 35mm²
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Additional equipment possibleYes
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92845

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

6A

Built-in depth

72mm

Rated voltage

400V

Release characteristic

C

Frequency

50 .. 60Hz

Voltage type

AC

Pollution degree

2

Number of protected poles

2

Width in number of modular spacings

2

Over voltage category

3

Explosion-proof

Power loss

3.12W

Degree of protection (IP)

IP20

Rated insulation voltage Ui

500V

Number of poles (total)

2

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Additional equipment possible

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.