Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Over voltage category3
Rated voltage400V
Rated insulation voltage Ui500V
Voltage typeAC
Release characteristicC
Rated current16A
Frequency50 - 60Hz
Built-in depth72mm
Connectable conductor cross section multi-wired35 - 35mm²
Explosion-proofNo
Width in number of modular spacings2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Connectable conductor cross section solid-core35 - 35mm²
Power loss4.98W
Number of poles (total)2
Number of protected poles2
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Additional equipment possibleYes
Degree of protection (IP)IP20
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92847

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Over voltage category

3

Rated voltage

400V

Rated insulation voltage Ui

500V

Voltage type

AC

Release characteristic

C

Rated current

16A

Frequency

50 .. 60Hz

Built-in depth

72mm

Connectable conductor cross section multi-wired

35 .. 35mm²

Explosion-proof

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Connectable conductor cross section solid-core

35 .. 35mm²

Power loss

4.98W

Number of poles (total)

2

Number of protected poles

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Additional equipment possible

Degree of protection (IP)

IP20

Pollution degree

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.