Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristicC
Built-in depth72mm
Number of poles (total)2
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated insulation voltage Ui500V
Additional equipment possibleYes
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Pollution degree2
Rated current50A
Connectable conductor cross section multi-wired35 - 35mm²
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Power loss9.56W
Voltage typeAC
Ambient temperature during operating-25 - 60°C
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp4kV
Over voltage category3
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Rated voltage400V
Width in number of modular spacings2
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92852 | MCB 2P C50 25KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

C

Built-in depth

72mm

Number of poles (total)

2

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated insulation voltage Ui

500V

Additional equipment possible

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Pollution degree

2

Rated current

50A

Connectable conductor cross section multi-wired

35 .. 35mm²

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Power loss

9.56W

Voltage type

AC

Ambient temperature during operating

-25 .. 60°C

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Over voltage category

3

Concurrently switching neutral conductor

Flush-mounted installation

Rated voltage

400V

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.