Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated insulation voltage Ui500V
Number of protected poles3
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Voltage typeAC
Flush-mounted installationNo
Frequency50 - 60Hz
Pollution degree2
Additional equipment possibleYes
Power loss9.06W
Width in number of modular spacings3
Rated impulse withstand voltage Uimp4kV
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Explosion-proofNo
Over voltage category3
Connectable conductor cross section solid-core35 - 35mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired35 - 35mm²
Rated current32A
Release characteristicC
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92870 | MCB 3P C32 25KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated insulation voltage Ui

500V

Number of protected poles

3

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Voltage type

AC

Flush-mounted installation

Frequency

50 .. 60Hz

Pollution degree

2

Additional equipment possible

Power loss

9.06W

Width in number of modular spacings

3

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Explosion-proof

Over voltage category

3

Connectable conductor cross section solid-core

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated current

32A

Release characteristic

C

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.