Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Built-in depth72mm
Rated current50A
Rated voltage400V
Release characteristicC
Over voltage category3
Rated insulation voltage Ui500V
Explosion-proofNo
Pollution degree2
Width in number of modular spacings3
Concurrently switching neutral conductorNo
Number of protected poles3
Degree of protection (IP)IP20
Flush-mounted installationNo
Number of poles (total)3
Connectable conductor cross section solid-core35 - 35mm²
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Connectable conductor cross section multi-wired35 - 35mm²
Power loss14.34W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V12.5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V20kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92872

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Built-in depth

72mm

Rated current

50A

Rated voltage

400V

Release characteristic

C

Over voltage category

3

Rated insulation voltage Ui

500V

Explosion-proof

Pollution degree

2

Width in number of modular spacings

3

Concurrently switching neutral conductor

Number of protected poles

3

Degree of protection (IP)

IP20

Flush-mounted installation

Number of poles (total)

3

Connectable conductor cross section solid-core

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Connectable conductor cross section multi-wired

35 .. 35mm²

Power loss

14.34W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA