Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Number of protected poles4
Rated insulation voltage Ui500V
Rated voltage400V
Voltage typeAC
Rated impulse withstand voltage Uimp4kV
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Power loss7.92W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Over voltage category3
Additional equipment possibleYes
Width in number of modular spacings4
Pollution degree2
Ambient temperature during operating-25 - 60°C
Rated current10A
Release characteristicC
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92886 | MCB 4P C10 25KA 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Number of protected poles

4

Rated insulation voltage Ui

500V

Rated voltage

400V

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Power loss

7.92W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Flush-mounted installation

Over voltage category

3

Additional equipment possible

Width in number of modular spacings

4

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Rated current

10A

Release characteristic

C

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.