Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristicC
Number of poles (total)4
Number of protected poles4
Built-in depth72mm
Rated current16A
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Voltage typeAC
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Flush-mounted installationNo
Power loss9.96W
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Pollution degree2
Width in number of modular spacings4
Over voltage category3
Connectable conductor cross section multi-wired35 - 35mm²
Explosion-proofNo
Connectable conductor cross section solid-core35 - 35mm²
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92887 | MCB 4P C16 25KA 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

C

Number of poles (total)

4

Number of protected poles

4

Built-in depth

72mm

Rated current

16A

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

AC

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Flush-mounted installation

Power loss

9.96W

Concurrently switching neutral conductor

Additional equipment possible

Degree of protection (IP)

IP20

Pollution degree

2

Width in number of modular spacings

4

Over voltage category

3

Connectable conductor cross section multi-wired

35 .. 35mm²

Explosion-proof

Connectable conductor cross section solid-core

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.