Technical specifications

Built-in depth72mm
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Voltage typeAC
Over voltage category3
Number of protected poles4
Rated voltage400V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Power loss14.92W
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Pollution degree2
Flush-mounted installationNo
Additional equipment possibleYes
Width in number of modular spacings4
Connectable conductor cross section solid-core35 - 35mm²
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Connectable conductor cross section multi-wired35 - 35mm²
Rated current40A
Release characteristicC
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW92891 | MCB 4P C40 25KA 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Voltage type

AC

Over voltage category

3

Number of protected poles

4

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

14.92W

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Pollution degree

2

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

4

Connectable conductor cross section solid-core

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated current

40A

Release characteristic

C

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA