Technical specifications

Built-in depth72mm
Number of protected poles1
Rated insulation voltage Ui500V
Rated voltage400V
Power loss7.4W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V16kA
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V4.5kA
Rated impulse withstand voltage Uimp6kV
Connectable conductor cross section multi-wired50 - 50mm²
Over voltage category4
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Pollution degree2
Additional equipment possibleYes
Frequency50 - 60Hz
Degree of protection (IP)IP20
Explosion-proofNo
Width in number of modular spacings1.5
Connectable conductor cross section solid-core70 - 70mm²
Rated current100A
Release characteristicC
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93308 | High Perf. MCB 1P C100 16KA 1,5M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated voltage

400V

Power loss

7.4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

4.5kA

Rated impulse withstand voltage Uimp

6kV

Connectable conductor cross section multi-wired

50 .. 50mm²

Over voltage category

4

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Pollution degree

2

Additional equipment possible

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Explosion-proof

Width in number of modular spacings

1.5

Connectable conductor cross section solid-core

70 .. 70mm²

Rated current

100A

Release characteristic

C

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA