Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage400V
Frequency50 - 60Hz
Power loss11.2W
Rated current80A
Built-in depth72mm
Over voltage category4
Voltage typeAC
Width in number of modular spacings3
Number of protected poles2
Rated insulation voltage Ui500V
Pollution degree2
Release characteristicC
Degree of protection (IP)IP20
Explosion-proofNo
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired50 - 50mm²
Connectable conductor cross section solid-core70 - 70mm²
Additional equipment possibleYes
Number of poles (total)2
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93327

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

400V

Frequency

50 .. 60Hz

Power loss

11.2W

Rated current

80A

Built-in depth

72mm

Over voltage category

4

Voltage type

AC

Width in number of modular spacings

3

Number of protected poles

2

Rated insulation voltage Ui

500V

Pollution degree

2

Release characteristic

C

Degree of protection (IP)

IP20

Explosion-proof

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

50 .. 50mm²

Connectable conductor cross section solid-core

70 .. 70mm²

Additional equipment possible

Number of poles (total)

2

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.