Frequency50 - 60Hz
Voltage typeAC
Release characteristicC
Rated voltage400V
Built-in depth72mm
Rated current125A
Explosion-proofNo
Pollution degree2
Over voltage category4
Width in number of modular spacings3
Rated insulation voltage Ui500V
Number of protected poles2
Number of poles (total)2
Power loss22W
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired50 - 50mm²
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Connectable conductor cross section solid-core70 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93329

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Frequency

50 .. 60Hz

Voltage type

AC

Release characteristic

C

Rated voltage

400V

Built-in depth

72mm

Rated current

125A

Explosion-proof

Pollution degree

2

Over voltage category

4

Width in number of modular spacings

3

Rated insulation voltage Ui

500V

Number of protected poles

2

Number of poles (total)

2

Power loss

22W

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

50 .. 50mm²

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Connectable conductor cross section solid-core

70 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.