Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated current125A
Width in number of modular spacings4.5
Pollution degree2
Built-in depth72mm
Rated insulation voltage Ui500V
Rated voltage400V
Power loss33W
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired50 - 50mm²
Over voltage category4
Frequency50 - 60Hz
Release characteristicC
Number of protected poles3
Concurrently switching neutral conductorNo
Voltage typeAC
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core70 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp6kV
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93339

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

125A

Width in number of modular spacings

4.5

Pollution degree

2

Built-in depth

72mm

Rated insulation voltage Ui

500V

Rated voltage

400V

Power loss

33W

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

50 .. 50mm²

Over voltage category

4

Frequency

50 .. 60Hz

Release characteristic

C

Number of protected poles

3

Concurrently switching neutral conductor

Voltage type

AC

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

70 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.