Technical specifications

Built-in depth72mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Rated voltage400V
Power loss11.2W
Voltage typeAC
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Flush-mounted installationNo
Over voltage category4
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Width in number of modular spacings3
Pollution degree2
Degree of protection (IP)IP20
Number of protected poles2
Connectable conductor cross section solid-core70 - 70mm²
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired50 - 50mm²
Rated current80A
Release characteristicD
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93377 | High Perf. MCB 2P D80 16KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Power loss

11.2W

Voltage type

AC

Concurrently switching neutral conductor

Additional equipment possible

Flush-mounted installation

Over voltage category

4

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Width in number of modular spacings

3

Pollution degree

2

Degree of protection (IP)

IP20

Number of protected poles

2

Connectable conductor cross section solid-core

70 .. 70mm²

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

50 .. 50mm²

Rated current

80A

Release characteristic

D

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA