Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Built-in depth72mm
Release characteristicD
Rated current100A
Over voltage category4
Rated voltage400V
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Number of protected poles3
Concurrently switching neutral conductorNo
Pollution degree2
Power loss22.2W
Explosion-proofNo
Degree of protection (IP)IP20
Width in number of modular spacings4.5
Ambient temperature during operating-25 - 60°C
Number of poles (total)3
Connectable conductor cross section solid-core70 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Additional equipment possibleYes
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section multi-wired50 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93388

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Built-in depth

72mm

Release characteristic

D

Rated current

100A

Over voltage category

4

Rated voltage

400V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Number of protected poles

3

Concurrently switching neutral conductor

Pollution degree

2

Power loss

22.2W

Explosion-proof

Degree of protection (IP)

IP20

Width in number of modular spacings

4.5

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

3

Connectable conductor cross section solid-core

70 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section multi-wired

50 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.