  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage400V
Built-in depth72mm
Release characteristicD
Explosion-proofNo
Over voltage category4
Rated current50A
Width in number of modular spacings6
Frequency50 - 60Hz
Pollution degree2
Rated insulation voltage Ui500V
Power loss16.8W
Voltage typeAC
Flush-mounted installationNo
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core70 - 70mm²
Number of poles (total)4
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired50 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp6kV
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93395

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

400V

Built-in depth

72mm

Release characteristic

D

Explosion-proof

Over voltage category

4

Rated current

50A

Width in number of modular spacings

6

Frequency

50 .. 60Hz

Pollution degree

2

Rated insulation voltage Ui

500V

Power loss

16.8W

Voltage type

AC

Flush-mounted installation

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

70 .. 70mm²

Number of poles (total)

4

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

50 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

6kV

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA