Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Release characteristicD
Rated insulation voltage Ui500V
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated current50A
Number of protected poles4
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Pollution degree2
Over voltage category4
Rated voltage400V
Width in number of modular spacings6
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Power loss16.8W
Additional equipment possibleYes
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired50 - 50mm²
Explosion-proofNo
Rated impulse withstand voltage Uimp6kV
Connectable conductor cross section solid-core70 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93395 | High Perf.mcb 4P D50 16KA 6M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

D

Rated insulation voltage Ui

500V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated current

50A

Number of protected poles

4

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Pollution degree

2

Over voltage category

4

Rated voltage

400V

Width in number of modular spacings

6

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Power loss

16.8W

Additional equipment possible

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

50 .. 50mm²

Explosion-proof

Rated impulse withstand voltage Uimp

6kV

Connectable conductor cross section solid-core

70 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.