  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Concurrently switching neutral conductorNo
Explosion-proofNo
Degree of protection (IP)IP20
Release characteristicC
Power loss8.4W
Connectable conductor cross section multi-wired50 - 50mm²
Width in number of modular spacings3
Over voltage category4
Connectable conductor cross section solid-core70 - 70mm²
Pollution degree2
Number of protected poles2
Rated voltage400V
Built-in depth72mm
Rated current50A
Rated insulation voltage Ui500V
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Frequency50 - 60Hz
Voltage typeAC
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp6kV
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93225

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Concurrently switching neutral conductor

Explosion-proof

Degree of protection (IP)

IP20

Release characteristic

C

Power loss

8.4W

Connectable conductor cross section multi-wired

50 .. 50mm²

Width in number of modular spacings

3

Over voltage category

4

Connectable conductor cross section solid-core

70 .. 70mm²

Pollution degree

2

Number of protected poles

2

Rated voltage

400V

Built-in depth

72mm

Rated current

50A

Rated insulation voltage Ui

500V

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Frequency

50 .. 60Hz

Voltage type

AC

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA