Technical specifications

Pollution degree2
Rated insulation voltage Ui500V
Over voltage category4
Frequency50 - 60Hz
Voltage typeAC
Built-in depth72mm
Rated voltage400V
Release characteristicC
Rated current32A
Number of protected poles3
Degree of protection (IP)IP20
Additional equipment possibleYes
Width in number of modular spacings4.5
Flush-mounted installationNo
Power loss9.3W
Connectable conductor cross section solid-core70 - 70mm²
Explosion-proofNo
Connectable conductor cross section multi-wired50 - 50mm²
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93233

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Pollution degree

2

Rated insulation voltage Ui

500V

Over voltage category

4

Frequency

50 .. 60Hz

Voltage type

AC

Built-in depth

72mm

Rated voltage

400V

Release characteristic

C

Rated current

32A

Number of protected poles

3

Degree of protection (IP)

IP20

Additional equipment possible

Width in number of modular spacings

4.5

Flush-mounted installation

Power loss

9.3W

Connectable conductor cross section solid-core

70 .. 70mm²

Explosion-proof

Connectable conductor cross section multi-wired

50 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA